Britec Electric Co., Ltd.

Britec Electric Co., Ltd.

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Type 2 Surge Protection Device /

BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector

Contact Now
Britec Electric Co., Ltd.
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MissMacy Jin
Contact Now

BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector

Ask Latest Price
Video Channel
Brand Name :BRITEC
Model Number :BR-40 3P+1
Certification :TUV/UL/CB/CE/ROHS
Place of Origin :China
MOQ :10 Piece/Pieces
Payment Terms :L/C, D/A, T/T, Western Union
Supply Ability :50000 Piece/Pieces Month
Delivery Time :Shipped in 15 days after payment
Packaging Details :EXPORT PACKING
Item Name :Type 2 surge arrester
Model Numbers :BR-40 3P+1
Waveform :8/20
Protection Class :IP20
Packing unit :1pc
Product Srtucture :Plug
EN type :Type2
Configuration :1P+1
MOQ :20PCS
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

3+1 surge protection device spd manufacture Type 2 surge arrester

Advantage:Common mode, differential mode full protection

Type 2 surge arrester Features:

Type 2 surge protectors are designed to be installed at the entrance of the installation, in the main switchboard, or close to sensitive terminals, on installations without LPS (lightning rods). These protectors are tested following the Class Ill test from IEC6 1643-11 or EN6 1643-11 standards and based on 8/20 us impulse current

Type 2 surge arrester Technology characteristic:

BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector

BR-40 3P+1
Max. continuous operating a.c. voltage Uc(L-N/N-PE) 320V/320V (50/60Hz)
Nominal discharge current (8/20us) In(L-N/N-PE) 20kA/20kA
Maximum discharge current (8/20us) Imax(L-N/N-PE) 40kA/40kA
Voltage protection level Up(L-N/N-PE) ≤1.5kV/≤1.5kV
Response time tA ≤25ns
Max. backup fuse 125A
Operating temperature range Tu -40℃—80℃
Cross-section area (Min.) 4mm2
Cross-section area (Max.) 35mm2
For mounting on 35mm Din rail
Enclosure material Thermal plastic UL94-V0
Test standards

IEC 61643-11, EN 61643-11


Type 2 surge arrester Dimension:

BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector

Type 2 surge arrester Application:

Application: Grid Power, AC Power Circuit, AC Distribution Box, LT Electrical Panel
AC SPD uses for AC Power or Grid Power to protect against transient ac voltage.

Type 2 surge arrester Certificate:

CB, CE, TUV,RoHS Certificate

BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector
Company information:

Wenzhou Britec Electric Co., Ltd. established in the year of 2003 and located in Yueqing, Zhejiang, China. Our company specialized in research and development of surge protection devices.The series of surge protection device Type 1 and Type 2 and Type 3, BR PV and SPDs for Data offer the market with a new choice of high quality surge arresters. We have 18 years of experience in the research & development and production of the surge protection field and provide 5 years warranty.
.

BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector
Production line:
BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector
BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector
Laboratory equipment:
BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector
BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector
Shipping:
BR-40 Type 2 Black Surge Arrester Protection Device 3P+1 IP20 Lightning Thunder Protector
FAQ:

Q1: Selection of surge protector

Al: The grading of the surge protector (commonly known as lightning protection) Is assessed according to the IEC61024 subdivision lightning protection theory, which is installed at the junction of the partition. Technical requirements and functions differ. The first-stage lightning protection device is installed between the 0-1 zone, high for the flow requirement, the minimum requirement of EN 61643-11 / IEC 61643-11 is 25 ka (10/350), and the second and third levels are installed between the 1-2 and 2-3 zones, mainly to suppress the overvoltage.

Q2: Are you a lightning surge protectors factory or lightning surge protectors trading company?

A2: We are a lightning surge protectors manufacturer.

Q3: Warranty and services:

A3:1. Warranty 5 years

2. lightning surge protectors products and accessories have been tested 3 times before ship out.

3. We own the best after-sale service team, if any problem happens, our team will do our best to solve it for you.

Q4: How can I get some lightning surge protectors samples?

A4: We are honored to offer you lightning surge protectors samples, pis contact our staff, and leave detailed contact information, we promise to keep your information confidential.

Q5: Is the sample available and free?

A5: Sample is available, but the sample cost should be payable by you. The cost of the sample will be refunded after further order.

Inquiry Cart 0